LOOP S PLUS KIT:Simple, yet powerful control and monitoring features through an integrated sidebar on an MFD showing dedicated functions. Output: 16 relays + 16 fuses.
Loop is a range of products, each of them flexible and customizable, granting control and navigation features in a single user interface previously accessible only via bigger systems. The integrated approach greatly reduces technical redundancy and device duplication, making Loop an inherently perfect choice for small to medium sized new and refitted boats. Loop uses Electromechanical digital switching
-Easy to install
-Easy to manage
-Easy to service
Acting directly on relay coil you are ALWAYS safe and sure to control the final load.
-The NAVIOP Loop S system is a system for on/off switching where the digital switches are available through the Control Bar.
-Each switch is provided with an LED signaling one of four statuses: ON (blue), OFF (grey), FAULT (red) or OVERRIDE (yellow)
OP-Box
-Processing and protocols Unit with PLC programming capability
AT 30
-J1939 – NMEA2K Gateway
-Provides logic for SwitchBar systems timers, etc
EGON
-Enables to eliminate the electrical panel and to manage the lines through a compact and cheap power distribution system.
-Reduces the cable necessary on a boat, considerably cutting down costs and time of wiring.
As a single and cumbersome electrical panel is not necessary anymore, it is possible to delocalize the power distribution system to better use rooms available on board.
Egon+ Board
Environmental
Operating temperature | -40 °C to 85 °C (104 °F to 185 °F) |
Storage temperature | -40 °C to 125 °C (104 °F to 257 °F) |
Mechanical shock SAE | J2030 (RDEC2002), Section 6.16 |
Bombardment test | 24 hour of dust, sand and gravel |
Salt fog | 96 hour period of salt fog per ASTM B117-94 |
Protection class | IP 66 |
Vibration | SAE J1455 (R2006), Section 4.10.4.2 |
Chemical resistance | Break fluid, AT fluid, antifreeze fluid, windshield wash fluid, PS fluid and oil. |
Abnormal conditions
Revers polarity protection | – 24 V DC, SAE J1455 (RJUN2006)- duration of 5 minutes |
Short circuit protection
Short to ground | 5 minutes, ER455 (R2008) Section 5.10.4 |
Short to 16 V DC | 5 minutes, ER455 (R2008) Section 5.10.4 |
Power up operation | Ramp battery voltage from 0 to min. operating voltage at 1 V/ms, |
Electrical
Power supply voltage | 12 V DC (8-16 V DC) |
Dielectric voltage withstanding | 80 V DC |
Current consumption | 1.5 mA battery quiescent current |
Total current limit | 200 A |
Total current limit per connector | 100 A |
Overload | 135% |
Temperature rise | 60 °C (140 °F) |
Insulation resistance | 10 MOhm |
Max load
Fuse channels | 30 A at 12 V DC |
Relay and fuse channels (resistive load) | 20 A at 12 V DC |
Maximum board load | 200 A |
Power connector | 2x M8 input studs, each rated at 100 A maximum |
Power wire size | Calculated based on total board consumption |
Output wire size | 1.31 mm² – 5.26 mm² (#10-16 AWG) |
Fuses | Mini blade fuse |
Relays | 280 footprint, 4 pin relay |
OP-BOX
Interface
Ethernet port | 2 (port 0 – 10/100, port 1 – 10/100) |
USB port | 1 (Host v. 2.0, max. 100 mA) |
Serial port | 2 (RS-232, RS-485, RS-422, software configurable, optical isolation) |
CAN bus port | 2 (optical isolation – 1kV) |
SD Card | No |
Expansion | No |
LED indicators | 5 (Power, Ethernet status) |
Ratings
Power supply | 9 to 32 V DC |
Current consumption | 0.15A max. at 24 V DC |
LEN | 0 |
Input protection | Electronic |
Battery | Yes |
Environment conditions
Operating temperature | -15°C to +55°C |
Storage temperature | -20°C to +70°C |
Operating / Storage humidity | 5 – 85% RH, non-condensing |
Protection class | IPx7 |