LOOP S KIT:Simple, yet powerful control and monitoring features through an integrated sidebar on an MFD showing dedicated functions. Output 8 relays + 8 fuses.
-The NAVIOP Loop S system is a system for on/off switching where the digital switches are available through the Control Bar.
-Each switch is provided with an LED signaling one of four statuses: ON (blue), OFF (grey), FAULT (red) or OVERRIDE (yellow)
OP-Box
-Processing and protocols Unit with PLC programming capability
AT 30
-J1939 – NMEA2K Gateway
-Provides logic for SwitchBar systems timers, etc
EGON
-Enables to eliminate the electrical panel and to manage the lines through a compact and cheap power distribution system.
-Reduces the cable necessary on a boat, considerably cutting down costs and time of wiring.
As a single and cumbersome electrical panel is not necessary anymore, it is possible to delocalize the power distribution system to better use rooms available on board.
Egon+ Board
Environmental
Operating temperature | -40 °C to 85 °C (104 °F to 185 °F) |
Storage temperature | -40 °C to 125 °C (104 °F to 257 °F) |
Mechanical shock SAE | J2030 (RDEC2002), Section 6.16 |
Bombardment test | 24 hour of dust, sand and gravel |
Salt fog | 96 hour period of salt fog per ASTM B117-94 |
Protection class | IP 66 |
Vibration | SAE J1455 (R2006), Section 4.10.4.2 |
Chemical resistance | Break fluid, AT fluid, antifreeze fluid, windshield wash fluid, PS fluid and oil. |
Abnormal conditions
Revers polarity protection | – 24 V DC, SAE J1455 (RJUN2006)- duration of 5 minutes |
Short circuit protection
Short to ground | 5 minutes, ER455 (R2008) Section 5.10.4 |
Short to 16 V DC | 5 minutes, ER455 (R2008) Section 5.10.4 |
Power up operation | Ramp battery voltage from 0 to min. operating voltage at 1 V/ms, |
Electrical
Power supply voltage | 12 V DC (8-16 V DC) |
Dielectric voltage withstanding | 80 V DC |
Current consumption | 1.5 mA battery quiescent current |
Total current limit | 200 A |
Total current limit per connector | 100 A |
Overload | 135% |
Temperature rise | 60 °C (140 °F) |
Insulation resistance | 10 MOhm |
Max load
Fuse channels | 30 A at 12 V DC |
Relay and fuse channels (resistive load) | 20 A at 12 V DC |
Maximum board load | 200 A |
Power connector | 2x M8 input studs, each rated at 100 A maximum |
Power wire size | Calculated based on total board consumption |
Output wire size | 1.31 mm² – 5.26 mm² (#10-16 AWG) |
Fuses | Mini blade fuse |
Relays | 280 footprint, 4 pin relay |
OP-BOX
Interface
Ethernet port | 2 (port 0 – 10/100, port 1 – 10/100) |
USB port | 1 (Host v. 2.0, max. 100 mA) |
Serial port | 2 (RS-232, RS-485, RS-422, software configurable, optical isolation) |
CAN bus port | 2 (optical isolation – 1kV) |
SD Card | No |
Expansion | No |
LED indicators | 5 (Power, Ethernet status) |
Ratings
Power supply | 9 to 32 V DC |
Current consumption | 0.15A max. at 24 V DC |
LEN | 0 |
Input protection | Electronic |
Battery | Yes |
Environment conditions
Operating temperature | -15°C to +55°C |
Storage temperature | -20°C to +70°C |
Operating / Storage humidity | 5 – 85% RH, non-condensing |
Protection class | IPx7 |